logo


Channel baffles: improving efficiency on trays with low vapor loading

Sour water strippers, wastewater benzene strippers, or any other column that operates with low vapor rates often have active areas that are easily oversized for the actual operating vapor traffic. For optimum tray efficiency, good contacting of the liquid flowing across the tray deck with the vapor flowing up through the tray orifices is critical. Channel baffles are a very straight-forward design modification that improve vapor/liquid contact, increasing tray efficiency in low vapor services. During an outage opportunity, replacement of existing tray active panels and bolted channel baffles can allow the column to improve overall separation and mass transfer.

The Challenge
To achieve maximum efficiency, a good tray design needs to have a sufficiently long flow path length (> 2 ft) and intense, uniform contacting between the vapor and liquid streams. In processes that simply do not have a lot of vapor traffic, the number of valves must be minimized to reduce open area and prevent weeping. This can often result in a very low valve density (large spacing between valves on the tray deck), allowing liquid to find flow pathways across the deck with minimal vapor contact.

The Solution
Channel baffles are vertical plates, bolted to the tray deck parallel to the liquid flow path. The area inside the baffles has active liquid and vapor traffic, while the area outside the baffles is a blanked zone.

In a channel baffle tray, the same open area and number of valves required for a full deck tray are installed in a restricted-width channel, increasing valve density while not sacrificing flow path length. Although liquid should not have a normal path through the blanked region, condensation from the open vapor space or normal froth height above the channel baffles can allow some liquid accumulation in the blanked regions. Sulzer incorporates features into the design to force liquid to flow only onto the channeled area, and to allow free draining of any accumulated liquids in the dead zone. 

An Example
When looking at the layout of a channel baffled tray, it is easy to see how vapor/liquid contact will improve. The schematic below illustrates the obvious change in valve density as a result of fitting the tray with channel baffles.  While exact efficiency is very dependent upon loadings, the "Tray B" design with the channel baffles will have a significantly higher efficiency than "Tray A".

DOWNLOAD LITERATURE

Sponsor:

Categories:

View More

  • Tray designs for extreme fouling applications

    Today refiners experience a lot of problems with processing of opportunity or heavy crudes. Such crudes have very high sulfur content and require the addition of amine scavengers before desalting. These amines decompose in the heater and create ammonium chlorides in the presence of water in the top of ...

  • Anti-fouling trays maximize coker main fractionator profitability

    The Coker Main Fractionator is systematically subjected to harsh operating conditions that can lead to deteriorating efficiency and performance due to coking and fouling. Poor reliability results in loss of profitable coking margins for the refinery. The main fractionator vapor feed from the coke drum ...

  • Improve separation in your column by increasing the number of trays

    Refiners often face revamp challenges when trying to improve separation within an existing column. Improving diesel recovery from gas oil, splitting benzene precursors from naphtha reformer charge, or simply minimizing product overlaps after capacity creep can all be difficult when limited by a fi xed ...

  • Gain 5-10% efficiency with this simple 4-pass tray revamp

    The design of 4-pass trays can be complex. It not only requires a close evaluation of the mechanical design but also the process response to that design at various flow rates. The balancing of the fluid flows across the tray can have a substantial effect on the tray performance, namely efficiency. Many ...

  • Proper design of mass transfer internals in the FCC flue gas scrubber can help reduce PM emissions

    The EPA’s New Source Performance Standards (40 C.F.R. §60.100-1-0, subpart Ja) regulates refinery particulate emissions, including the discharge of catalyst fines from the FCCU flue gas scrubber stack. Because refiners have traditionally correlated particulate matter (PM) emissions with FCCU ...

  • Improve fouling resistance in your wastewater benzene stripper

    Benzene stripper columns, built so that refineries can meet the National Emissions Standards for Hazardous Air Pollutants (NESHAP), operate with several unique conditions – low vapor rates, high liquid loads, and a high tendency toward fouling make designing well-balanced, effective internals difficult. The ...

  • Important tray design features that improve column operating reliability

    How often does Maintenance personnel open a column during a shutdown and find tray panels fallen without any obvious damage? How about tray valves stuck in the bottoms pump suction? While the initial reaction may be to blame faulty installation where the hardware was not properly tightened, the answer ...

  • Green design practices: focus on efficiency

    Green design is more than recycling scrap materials or calculating carbon footprints. It minimizes negative environmental impact through skillful design and operating practices to produce efficient, better-functioning processes. Because green practices reduce resource requirements, in many cases, they ...

  • 4 simple ways to convert turnarounds into profitable tower upgrade opportunities

    With planned outages commonly occurring at intervals of 2-5 years, a refinery turnaround is a prime opportunity to replace column and separator internals with the newest available technology. Planning for an outage with a “replacement-in-kind” strategy will address lost performance from refinery ...

  • Maximizing light cycle oil recovery in the FCC main fractionator

    Refiners operating FCCU's have adjusted their operating strategies to maximize light cycle oil production to meet the increased demand for automotive diesel. Catalyst formulations and reactor conditions can alter yields, but the refinery cannot take full advantage of the increased LCO recovery without ...