Literature

At-Line gasoline and diesel analysis to ensure product quality

Fast and comprehensive analysis on fuel quality is important to ensure product quality in the process, as well as during transportation. In a quick at-line fuel test the MINISCAN IRXpert allows to check product contamination and adulteration. Using infrared spectroscopy in combination ...


Clora 2XP: Sub-ppm chlorine analysis

Clora® 2XP is designed for use with liquid hydrocarbons such as aromatics, distillates, heavy fuels and crude oils, as well as aqueous solutions. The enhanced precision of Clora 2XP is ideal for testing related to catalyst poisoning in reformers or for sites with fluid catalytic crackers ...


Clora Online: Continuous chlorine analysis in process streams

Chlorine contributes significantly to the corrosion of plant equipment and must be treated accordingly. With ever-changing crude quality and potential for process upsets, chlorine levels can shift quickly, making real-time analytical results invaluable. Powered by MWDXRF®, Clora® ...


Clora: Monitor chlorine in liquid hydrocarbons

Clora® is a compact analyzer to measure total chlorine in liquid hydrocarbons such as aromatics, distillates, heavy fuels, crude oils, and aqueous solutions. Clora delivers unprecedented accuracy and precision for petroleum and petrochemical applications where ease-of-use, reliability ...


Comparing physical solvents for acid gas removal

Physical solvents such as DEPG, NMP, Methanol, and Propylene Carbonate are often used to treat sour gas. These physical solvents differ from chemical solvents such as ethanolamines and hot potassium carbonate in a number of ways. The regeneration of chemical solvents is achieved by the ...


Crude oil contaminants: chlorine and the desalting process

Crude oil contains many contaminants which present challenges to refiners. Some contaminants occur naturally in the crude oil and others are accumulated in the upstream process. The primary means to remove these contaminants is the desalting process.


Exchanger leak testing - chemical tracers

Tracerco has been at the forefront of the development of online leak detection for the last 40 years. The method allows the detection of leaks as small as 0.5%. However, customer demands to measure smaller leaks affecting product quality, has prompted extensive research to develop alternative ...


Flow-pressure of lubricating grease according to DIN51805 kesternich

Flow-properties of lubrication grease at low temperatures are a measure of great significance for central lubrication systems of vehicles and machineries. This property can best be measured according to the method of Kesternich (DIN 5108). The original manual and time-consuming method ...


Fuels analysis made simple

Analyzing finished fuels and feedstocks is a complicated process traditionally involving multiple analytical techniques, expensive dyes; multiple columns, valves, and traps; messy solvents; complicated hardware; and lots of analysis time. In order to obtain meaningful results, all of these ...


Gas processing

ProMax® is a powerful and versatile process simulation package that is used worldwide to design and optimize gas processing, refining and chemical facilities. Totally integrated with Microsoft Visio®, Excel® and Word®, ProMax is the best simulation tool for designing gas ...


Haldor Topsoe refinery walk-through

Exploring the hidden potential of your refinery. Refinery processes are complex and filled with potential sources of inefficiency. A Topsoe Refinery Walk-Through will identify the hidden opportunities and help you improve the refinery profitability, flexibility, safety, and reliability. Within ...


Hoekstra war stories

In the past two years, there have been many field failures in ultra-low sulfur diesel (ulsd) hydrotreaters. By field failures we mean short cycles of less than half the expected cycle life. The root cause of these failures was overestimating what a catalyst can do in a hydrogen starved ...


How much time can you save by switching to Sindie 2622 Gen3?

Sindie 2622 is renowned for its precision, accuracy, and ease of use. However, one drawback to the ASTM D2622method is the requirement for duplicate determinations of samples ≤100 ppm. This equates to 20 minutes of measurement time on the traditional Sindie 2622 Gen2 [(300s background ...


indie 2622: 2622 & 7039 sulfur analysis as low as 0.15 ppm

Sindie® 2622 Gen 3 complies with ASTM D2622, D7039 and ISO 20884 methods, enabling complete flexibility in sulfur analysis. With no compromises in detection, performance and reliability, Sindie 2622 is the ideal sulfur analytical solution from ultra-low sulfur diesel and gasoline to ...


Interface measurement in desalters

Interface measurements in desalters are often regarded as not being very critical, even though every drop of oil, to be refined, passes through the desalter. As refineries try to maximize their margins, so-called opportunity crudes are often used. These crude oils generally contain increased ...


MINISCAN IR LOG

LOGical Solution for Condition Monitoring of Lubricants, Oils and Greases. The MINISCAN IR LOG is a highly versatile and extremely fast FTIR analyzer, designed for on-site condition monitoring of oils and greases. It is also capable of measuring low or high levels of water in oil accurately ...


MINISCAN IR VISION - top performer in portable fuel analysis

The MINISCAN IR VISION is a high speed, compact and robust FTIR fuel analyzer for the comprehensive and automatic measurement of gasoline, jet and diesel fuels. The analyzer is configured to measure more than 100 fuel parameters and components for fuel blending, for quality inspection ...


MINIVAP VP Vision - next generation vapor pressure testing

MINIVAP VP Vision is a highly versatile portable vapor pressure tester that features best-in-class precision and a pressure range of 0-2000 kPa. It is the first analyzer that demonstrates excellence in engineering by earning certificates for robustness and durability. Based on Grabner´s ...


Optimizing CO2 capture, dehydration and compression facilities

The removal of CO2 by liquid absorbents is widely implemented in the field of gas processing, chemical production, and coal gasification. Many power plants are looking at post-combustion CO2 recovery to meet environmental regulations and to produce CO2 for enhanced oil recovery applications. ...


ParaFuel™ NIR process analyzer

Comprehensive fuel and crude oil analysis through NIR spectroscopy. The ParaFuel™ NIR Process analyzer from LT Industries provides comprehensive inline analysis of Diesel, Gasoline, Jet Fuel, Kerosene, Crude Oil, Blending components and Blended Fuels for a wide range of critical ...


Phoebe: Total phosphorus analysis as low as 0.4 ppm

From crude oil to bio-fuels, in additives or water, Phoebe® delivers unprecedented precision and accuracy for quantification of phosphorus. Phoebe delivers a LOD of 0.4 ppm in hydrocarbon matrices in a ten-minute measurement cycle.


ProMax®

ProMax is built on over 40 years of continual research and development efforts. Our team of development engineers has consistently found innovative ways to model processes so that the end results accurately refl ect the actual operating conditions of gas processing, refi ning and chemical ...


Quick at-line mini-distillation delivers true boiling point or D86 results

The MINIDIS ADXpert is a compact, versatile true atmospheric distillation unit, used for the quick and accurate quality control of Gasoline, Jet Fuels, Diesel, Biofuels, Blends, Chemicals and Solvents in laboratories and in process. A distillation run on light products takes just 15 minutes ...


RVP in process: ensure safety, comply with specifications, optimize profits

Pipeline operators, offshore platforms, terminals, fuel depots or oil tankers detect the vapor pressure, before transporting crude oil or other petrochemical products such as Gasoline or LPG for subsequent processing. It is absolutely necessary to know the vapor pressure of the transported ...


S, Ni, V, and Fe analysis of crude oil using HDXRF®

Test methods for measuring sulfur content, like ASTM D4294 and ISO 8754, have become critical for assessing the value of crude oil. The blending of crude oils from different sources has become more commonplace within the industry to meet specifications for the classification of sweet crude ...


Safe flash point testing of refined products, oils and chemicals

Flashpoint testing is required in a number of industries to ensure conformance with regulatory requirements. It is used to assess, how much care has to be taken in handling, transporting and storing chemicals or solvents, e.g. Diesel, Jet Fuels, Biofuels, Asphalt, Waste Water, Lube Oils, ...


Selecting the best solvent for gas treating

Selecting the best amine/solvent for gas treating is not a trivial task. There are a number of amines available to remove contaminants such as CO2, H2 S and organic sulfur compounds from sour gas streams. The most commonly used amines are monoethanolamine (MEA), diethanolamine (DEA), and ...


SERVOTOUGH FlueGasExact 2700

High performance combustion process analysis of oxygen and combustibles, designed for use in the most hazardous and challenging location. Armed with an integral sampling system custom-designed for operation in some of the hottest and most extreme combustion environments, the FluegasExact ...


SERVOTOUGH SpectraExact 2500

Rugged photometric multigas gas analyzer designed for demanding process applications. Designed to provide a highly flexible analytical solution adaptable to many applications, the SpectraExact (2500) range delivers a winning combination of proven performance and flexible operation in a ...


SERVOTOUGH SpectraScan 2400

Tunable filter infrared absorption on-line gas analysis platform ideal for the measurement of light hydrocarbons. The SERVOTOUGH SpectraScan is a real-time Tunable Filter Infrared analyzer capable 
of accurately separating light hydrocarbon components. Using a unique wavelength scanning ...


Signal: Total silicon analysis as low as 0.65 ppm

From gasoline to ethanol and toluene, Signal® delivers total silicon analysis. Powered by MWDXRF®, Signal is a robust analysis solution for demanding petroleum and industrial environments.


Sindie +Cl: Measure both sulfur and chlorine with one instrument

Sindie +Cl is a two-in-one instrument enabling trace analysis of both sulfur and chlorine with one push of a button. It is the ideal solution to certify sulfur levels in finished products, assess chlorine for corrosion mitigation, and optimize process parameters.


Sindie +Pb: Sulfur plus lead in petroleum products

As aviation industry requirements become more stringent, lead detection is critical in such products as aviation gasoline and jet fuel. Sindie® +Pb delivers unprecedented precision and accuracy for sulfur and lead detection.


Sindie 7039: 7039 sulfur analysis as low as 0.15 ppm

From ultra-low sulfur diesel and gasoline, to heavy fuel oil and crudes, Sindie® 7039 Gen 3 delivers improved precision and accuracy. Sindie 7039 is the ideal analytical solution for the refining industry where detection, performance and reliability are critical.


Sindie Online: Continuous sulfur analysis in hydrocarbon process streams

Sindie® Online is an industrial grade process sulfur analyzer with breakthrough detection capability to monitor ultra-low sulfur in petroleum or aqueous process streams. This process analyzer presents the ultimate solution for refineries and pipeline terminals where measurement speed ...


Sindie OTG: Portable sulfur analysis

Sindie® OTG is a portable sulfur analyzer, delivering reliable and precise results in hydrocarbons from ULSD and gasoline to marine fuels and crudes. Operate in-the-field, on-board marine environments, and in laboratories. Sindie OTG complies with ASTM D7039 and ISO 20884.


Sub-ppm chloride monitoring of hydrocarbons

Corrosion at petroleum refineries is a critical problem all over the world. In the United States alone, NACE International, a professional association dedicated to reducing the economic impact of corrosion, has shown that $3.7 billion in direct costs are realized annually from maintenance, ...


Sulfur in jet fuel by ASTM D4294

The International Air Transport Association (IATA) reports that in 2017 alone, more than 4 billion passengers traveled by air. It is estimated that air transport will reach global growth of over 7 billion passengers by 2035. Standard jet fuel specifications are used to ensure that wherever ...


Sulfur recovery

With increasing environmental concerns, sulfur recovery has become one of the leading issues in emissions reduction. Bryan Research & Engineering’s process simulator, ProMax, contains a complete reactor suite for modeling kinetic (plug flow and stirred tank), equilibrium, conversion, ...


Topsoe refinery Research & Development

Providing refiners with the best catalysts on the market would be impossible without the innovative ideas from Topsoe R&D. Combined with the knowledge obtained from our pilot plant units, catalyst development is essential to providing high-performing, customized solutions. Topsoe’s ...