Echotel® Model 961/962 ultrasonic level switches
Increasing demands for compliance with safety systems and overfill protection has mandated more reliable point level measurement. Echotel® Models 961 & 962 Ultrasonic Level Switches meet these demands with advanced transducer designs, extensive hazardous location approvals, and a new self-test technology.
Model 961 offers the ultimate solution to reliable single point liquid level measurement. This advanced switch uses pulsed signal technology for superior performance in difficult process conditions, and to provide excellent immunity from sources of electrical noise interference. Extensive self-testing of the electronics and transducer make this advanced switch suitable for use in Safety Integrity Level (SIL) 2 loops.
Model 962 is a dual point switch that can be used as a level controller, or to control pumps in an auto fill or auto empty mode. The tip sensitive lower gap performs well in aerated or foamy liquids, and can measure to within 1⁄4" of the vessel bottom. The rigidity of the unique flow-through upper gap allows separations of up to 128" (325 cm) between the upper and lower transducer gaps.
Features
• Single or dual point liquid level measurement
• Advanced self-test technology provides
unsurpassed testing of electronics, transducer,
piezoelectric crystals, and electromagnetic noise
• Adjustable time delay for turbulent aerated liquids
• Relay output or mA current shift with separate
malfunction indication
• Integral or remote mount electronics
• Pulsed signal technology
• Extensive FM, CSA, and ATEX explosion proof and
intrinsically safe approvals
• Suitable for Safety Integrity Level (SIL) 2 loops
Applications
• High level alarm
• Low level alarm
• Overfill protection
• Pump protection
• Seal pot level
• Pump control
Industries
• Chemical
• Petrochemical
• Pulp and paper
• Food and pharmaceutical
• Power
• Water and wastewater
Sponsor:
-
Echotel® Model 961/962 ultrasonic level switches
Increasing demands for compliance with safety systems and overfill protection has mandated more reliable point level measurement. Echotel® Models 961 & 962 Ultrasonic Level Switches meet these demands with advanced transducer designs, extensive hazardous location approvals, and a new self-test ...
-
ECHOTEL® ultrasonic level switches
The more you rely on ECHOTEL ultrasonic level switches, the less you will worry if a tuning fork is up to the job of providing the outstanding quality, reliability and overfill prevention your facility needs. ECHOTEL® ultrasonic switches provide continuously accurate and reliable level control that ...
-
Thermatel® enhanced model TA2 thermal mass flow meter
The Thermatel® Enhanced Model TA2 Thermal Mass Flow Meter provides reliable mass measurement for air and gas flow applications. The powerful, yet easy to use, electronics are contained in a compact explosion proof enclosure. The TA2 is available with both insertion probes as well as flow body design ...
-
Eclipse® 706 guided wave radar
An Introduction to Guided Wave Radar Technology. When MAGNETROL introduced guided wave radar technology to liquid level applications for the process industry, it filled a critical need of providing exceptionally robust level measurement under challenging process conditions. Guided wave radar continues ...
-
Level instruments for tank overfill prevention
Tank overfill incidents in recent years have resulted in loss of life and billions of dollars in damages to petroleum facilities worldwide. One of the worst incidents — the overflow of a gasoline storage tank at Buncefield Oil Depot (U.K.) — has been traced to the failure of level control ...
-
Displacer type liquid level switches
Magnetrol® displacement type level switches offer the industrial user a wide choice of alarm and control configurations. Every unit utilizes a simple buoyancy principle and is well suited for simple or complex applications, such as foaming or surging liquids or agitated fluids, and usually costs ...
-
Digital E3 Modulevel® liquid level displacer transmitter
Outstanding output stability, structural integrity and ease of use make range spring technology a better level control solution than torque tubes. Avoid the twists and turns of torque tube technology, which can’t equal the performance, durability and ease of use of a range spring. The E3 MODULEVEL ...
-
Digital E3 Modulevel® technology overview
Outstanding output stability, structural integrity and ease of use make range spring technology a better level control solution than torque tubes. Avoid the twists and turns of torque tube technology, which can’t equal the performance, durability and ease of use of a range spring. The E3 MODULEVEL ...
-
Petroleum Refining: a guide to level and flow control for gasoline refineries
Throughout refineries, level and flow instrumentation plays a critical role in improving efficiency and safety in separation, conversion, treatment and blending processes.
-
Crude Oil Processing: level and flow instrumentation for onshore and ofshore
Crude and water stream level and flow controls enhance safety and efficiency throughout upstream applications, including separation, dehydration, desalting, degassing, vapor recovery, storage tanks and more.