Improve fouling resistance in your wastewater benzene stripper

Benzene stripper columns, built so that refineries can meet the National Emissions Standards for Hazardous Air Pollutants (NESHAP), operate with several unique conditions – low vapor rates, high liquid loads, and a high tendency toward fouling make designing well-balanced, effective internals difficult.

The Problem: Two Refinery Case Studies
Sulzer was contacted by two separate refiners who noted a continued fouling problem and short run lengths on their wastewater strippers. The configuration of the units was very similar, with both strippers processing wastewater from the desalters, coker blowdown, and various waste sumps from around the refinery.

Refiner “A” was operating a retrofitted column, formerly utilized as a Coker Main Fractionator. They wanted to install new internals to fit within the existing tray support rings to avoid welding on a stress-relieved vessel. They targeted an increase in runlength from 8 weeks to 6 months.

Refiner “B” had noted their fouling problem becoming worse with opportunity crudes being processed. They were batching flow to the Stripper, with a surge tank upstream. Refiner “B” was controlling stripping steam injection to maintain a middle tray temperature target. They had planned to replace the trays in kind, but wanted to investigate other options before the next outage for cleaning.

The Strategy
Benzene steam stripper columns tend to have very low vapor rates as the refiner seeks to minimize energy consumption and steam usage. The vapor load on the top trays is primarily stripped hydrocarbon, with much of the steam having condensed on the lower trays. The low vapor rates are coupled with high liquid rates, which can make a good, balanced tray design tricky.

Without the appropriate stripping steam, the top vapor loads can be non-existent. Sulzer starts with a simple heat balance in the column. A significant amount of latent heat from the steam is transferred to sensible heat in the water and unable to be used to strip the benzene. Steam injection must be sufficient to where enough steam remains in the vapor phase or no tray design will be successful in this application.

An anti-fouling tray design should be considered. There are several features that Sulzer implements in many services to reduce fouling accumulation like a deck design to reduce stagnation zones, high performance downcomers to enhance liquid disengagement, and large fixed valves like the Sulzer V-Grid™ LVG trays.

The Solutions
Presented with an anti-fouling tray option or a less efficient shed deck option, Refiner A chose to equip their column with V-Grid LVG trays and channel baffles in order to create an active area with adequate sweep of liquid and adequate valve density to maintain efficiency.

For Refiner B, Sulzer recommended an alternate control scheme to maintain a stripping steam to feed rate ratio, ensuring that the system had adequate duty to strip out benzene. The Refiner B Stripper was equipped with antifouling trays, featuring sloped downcomers to keep a higher velocity in order to sweep solids from the exit.

The Payout
Refiner B was able to increase run length on their tower by contacting the Sulzer Refinery Applications Team prior to replacing their internals in kind. Check with your Sulzer representative to see if you have upgrade potential with your in-kind replacements. At very little cost difference, you’ll realize

DOWNLOAD LITERATURE

View More

  • Safeguard packed column efficiency with proper liquid distribution

    Initial liquid distribution directly affects the efficiency of structured and random packing beds. As such, some form of flow test should be conducted to validate distributor performance prior to column startup. Steady state water flow testing is the most common method of testing distributors. It can ...

  • Separator technology reduces refinery operating costs and downtime

    A US refining company contacted us to discuss a separation problem in the feed to an alkylation process. Caustic entrainment from their selective hydrogenation unit was poisoning the hydrofluoric acid catalyst in the alkylation unit. The continuous phase feed to the alkylation unit consisted of ~180m3/hr ...

  • Tray designs for extreme fouling applications

    Today refiners experience a lot of problems with processing of opportunity or heavy crudes. Such crudes have very high sulfur content and require the addition of amine scavengers before desalting. These amines decompose in the heater and create ammonium chlorides in the presence of water in the top of ...

  • Anti-fouling trays maximize coker main fractionator profitability

    The Coker Main Fractionator is systematically subjected to harsh operating conditions that can lead to deteriorating efficiency and performance due to coking and fouling. Poor reliability results in loss of profitable coking margins for the refinery. The main fractionator vapor feed from the coke drum ...

  • Improve separation in your column by increasing the number of trays

    Refiners often face revamp challenges when trying to improve separation within an existing column. Improving diesel recovery from gas oil, splitting benzene precursors from naphtha reformer charge, or simply minimizing product overlaps after capacity creep can all be difficult when limited by a fi xed ...

  • Gain 5-10% efficiency with this simple 4-pass tray revamp

    The design of 4-pass trays can be complex. It not only requires a close evaluation of the mechanical design but also the process response to that design at various flow rates. The balancing of the fluid flows across the tray can have a substantial effect on the tray performance, namely efficiency. Many ...

  • Proper design of mass transfer internals in the FCC flue gas scrubber can help reduce PM emissions

    The EPA’s New Source Performance Standards (40 C.F.R. §60.100-1-0, subpart Ja) regulates refinery particulate emissions, including the discharge of catalyst fines from the FCCU flue gas scrubber stack. Because refiners have traditionally correlated particulate matter (PM) emissions with FCCU ...

  • Improve fouling resistance in your wastewater benzene stripper

    Benzene stripper columns, built so that refineries can meet the National Emissions Standards for Hazardous Air Pollutants (NESHAP), operate with several unique conditions – low vapor rates, high liquid loads, and a high tendency toward fouling make designing well-balanced, effective internals difficult. The ...

  • Important tray design features that improve column operating reliability

    How often does Maintenance personnel open a column during a shutdown and find tray panels fallen without any obvious damage? How about tray valves stuck in the bottoms pump suction? While the initial reaction may be to blame faulty installation where the hardware was not properly tightened, the answer ...

  • Green design practices: focus on efficiency

    Green design is more than recycling scrap materials or calculating carbon footprints. It minimizes negative environmental impact through skillful design and operating practices to produce efficient, better-functioning processes. Because green practices reduce resource requirements, in many cases, they ...

  • Responsive image Galexia™ hydroprocessing platform
  • Responsive image Reinventing reliability
  • Responsive image Worldwide refinery processing review
  • Responsive image Processing heavy canadian crude
  • Responsive image The sulphur processing expert
  • Responsive image OpX® Digital
  • Responsive image ProTreat® mass transfer rate based simulation
  • Responsive image Extensive tray portfolio
  • Responsive image PROVALVE® Fixed Valve
  • Responsive image Corrosion control
  • Responsive image Shut-off valves